Sterling heights, michigan 483142117 18005210398 fax 810 2540485 installation of multiple header sections for display door units consisting of 4 or more doors, it is necessary to temporarily support the header while erecting the cooler. Because they are a dropin replacement for existing shaded pole and psc motors, installation is quick and easy. This video is an animation of how the refrigeration cycle works, with each components function. Src walkin installation instructions pg 5 6620 nineteen mile rd. Each evaporator unit must be installed using proper refrigeration. Walkin unit coolers heatcraft worldwide refrigeration. Evaporator temperatures r22 r404ar507 evaporator temperature. Bohn is an industry leader in unit coolers, condensing units, and fluid coolers developed for grocery stores, restaurants, and other professional kitchens. New heatcraft adt090sk 9000 btu 1151 evaporator with txv and ec motors. Prices and speciffications subject to change without notice.
Installation and operation manual heatcraft worldwide refrigeration. When compressor vapor, in reverse cycle defrosting, is directed back into the evaporator at the suction connection, it. Heatcraft the name behind the brands you trust our stateoftheart manufacturing facilities in the cities of stone mountain, columbus and tifton, georgia, produce evaporators, condensers, merchandise display cases and other topquality refrigeration products for our six marketleading brands. Center mount unit coolers sm air defrost models sme electric defrost models. Make offer new heatcraft adt090sk 9000 btu 1151 evaporator. Refer to the evaporator coil drawing dimension for mounting holes location. Do not leak test system above transformer is in each evaporator, the voltage tap must be set on each occur. Condensing units himcu heat pump pdf manual download. Ensure that the operating instructions are accessible to all people that have anything at all to do with the unit at all times. Jul 02, got a heatcraft walkin cooler the wiring diagram is completely gone, including the panel the diagram should be on. Do not install the evaporator too close to door openings to prevent icing problems. Be careful not to damage the grill during installation.
Bohn reserves the right to make changes in specifications or design, at any time, without. Bohn evaporator manual we manufacture unit coolers, condensers, dry coolers, compressorized racks, heatcraft refrigeration products provides climatecontrol solutions for commercial refrigeration and industrial cooling applications, download bohn evaporator manual pdf. Installation video, how to hang an evap, walkin cooler, walkin evaporator, hvac install. Product literature commercial refrigeration brochures heatcraft. Order from heritage parts the leading online provider of oem commercial kitchen replacement parts. Condensing units heatcraft worldwide refrigeration. These instructions are intended as a general guide and do not supersede local or national codes in any way. Easy to install and service panels on ends quickly. Kmp medium profile evaporators keeprite refrigeration. Installation and operation manual refrigeration mechanics. It mounts to the top of the refrigerator and discharges cold air against the back wall.
Available on all new equipment or as an easyto install, dropin replacement aftermarket part from interlink commercial refrigeration parts. See himuc installation and operation manual for more details. The system as supplied by bohn heatcraft, was thoroughly cleaned and dehydrated at the factory. Some general rules for evaporator placement which must be followed. Connect unit to power supply using the cord with plug, if provided, or hard wire. Some general rules for evaporator placement which must be. For over 70 years, trenton refrigeration has been a leader in the commercial refrigeration industry due to our commitment to innovation and dedication to supporting our customers. The ec motor is an energy sufficient option on bohn low profile evaporators. Bohn installation manual free download as pdf file. Typical wiring diagram for single evaporator with and without defrost timer. Bohn provides an unmatched selection of precisely engineered systems and responsive customer service. Minimum clearance between evaporator and the walls is equal to or greater than the coil height for proper air flow and service access.
Low profile unit coolers unit coolers recommended unit cooler placement some general rules for evaporator placement which must be followed are. View online or download bohn adt104 technical manual. Walkin installation instructions src refrigeration. Consult authorities who have jurisdiction before installation. Heatcraft refrigeration products user manuals download.
The defrost requirements will vary on each installation so. Bohn installation manual heat exchanger thermostat scribd. Condensing unit and refrigeration system installation. Their refrigeration systems help reduce installation costs and keep your coolers running efficiently, costing you less in resources and money. Standard features cabinet design features front access panels on each side for easy access to. View and download heatcraft himqrc installation and operation manual online.
After installation, the fieldinstalled lines are to be evacuated to a vacuum of 500 microns or less and held for at least one hour. Manual covering commercial refrigeration cooling and freezing. Shipping and packing list package 1 of 1 contains the following. Schematics in this installation testing is complete.
Installation and maintenance to be performed only by certi. Installation and table of contents operation manual. Make offer new bohn evaporator bhg640dpea heatcraft hot gas defrost 6fpi 64,000btuh. Product literature commercial refrigeration brochures. Ensure that the condenser air flow is not obstructed. These are general guidelines that may have to be tailored to. Heatcraft refrigeration products condensing units installation and operation manual. Freezer walkin evaporator explained part 1 of 3 youtube. Bohn low air flow unit coolers optional liquid line bypass kit for reverse cycle hot gas defrost the wkg may be field piped for reverse cycle defrost using the optional bypass kit. Installation and maintenance to be performed only by qualified personnel who are familiar. Whether youre upgrading your current system, replacing old equipment or starting from the ground up, you can count on bohn for reliable, quiet performance, as well as energy savings and lower overall operating costs. The ec motor is an energy solutions option on new bohn low profile evaporators. With this air flow pattern, the air is not blasted on the product but is diffused along the back wall and then gently drawn across the product as it returns to the unit. Heatcraft refrigeration products condensing units himcu manual online.
Refrigeration products hrp brands including bohn, larkin, climate control and chandler. Evaporator iom guidelines for the installation, operation and maintenance of heatcrafts direct expansion dx cooling coils have been provided to help insure proper performance of the coils and their longevity. Bohn commercial refrigeration equipment for sale ebay. Commercial refrigeration products trenton refrigeration. Install energy efficient evaporator fan motors walkin refrigeration. Install energy efficient evaporator fan motors walkin. Heatcraft refrigeration product brochures, technical handbooks and installation instructions for heatcraft commercial and industrial refrigeration products. Owners operating instructions 25 x 25 panel opening required for evaporator section of medium cabinet sizes. Low profile unit coolers heatcraft worldwide refrigeration. Utilizing the experience and expertise of our team, trenton refrigeration consistently. Trenton refrigeration stands for reliable, troublefree operation in an extensive line of quality products backed up with advanced design features. View and download heatcraft refrigeration products condensing units himcu installating and operation manual online. Because theyre a dropin replacement for existing shaded pole and psc motors, installation is quick and easy. Install the trim around the inside opening with the hardware provided.
1110 998 1418 127 380 1271 1059 1505 1437 195 628 36 257 1105 582 1630 252 442 734 876 834 358 644 129 1464 516 1179 1264